Formwork plywood span: joist spacing calculator

In short

Under a 200 mm slab, an 18 mm film-faced panel with a bending stiffness of 3,600 N/mm² (EN 636 class E 40) spans about 450 mm between joists before it deflects more than span ÷ 360, on three or more spans. That uses the ACI 347R-14 loads (concrete weight plus 2.4 kN/m² construction live load, at least 4.8 kN/m² in all) and takes our ±0.5 mm tolerance off the thickness. It is a planning estimate: PK Ply claims no stress grade, and a qualified engineer checks and signs off the formwork design.

  • Planning estimate only
  • ACI 347R-14 loads
  • EN 636 stiffness classes
  • ±0.5 mm taken off
  • 12, 15, 18, 21 mm
  • Engineer signs off
Formwork plywood span: bar chart of the largest joist spacing under a 200 mm slab at EN 636 class E 40 and span ÷ 360: 12 mm about 296 mm, 15 mm 373 mm, 18 mm 450 mm, 21 mm 527 mm
Largest joist spacing by thickness for a 200 mm slab at EN 636 class E 40 and span ÷ 360: a planning estimate.
18 mm, 200 mm slab, E 40, span ÷ 360
about 450 mm
12 mm, same case
about 296 mm
21 mm, same case
about 527 mm
thickness tolerance, taken off
±0.5 mm

Video

Reading the span estimate

How far can a panel span · 2:03, English captions

Calculator

Joist spacing and deflection

Choose slab or wall, the panel thickness, the stiffness class from the panel’s declaration of performance, the supports and the deflection limit your engineer sets.

For a wall or column face, switch the load case and enter the lateral pressure; the concrete pressure calculator works it out from the pour rate and temperature. The stiffness options are the lower limits of the EN 636 bending modulus classes, which the standard itself says are not for structural design. Your engineer uses the values declared for the panel actually ordered.

Load on the sheet
7.11 kN/m²
Thickness used
17.5 mm
Bending stiffness EI per metre width
1.61 kN·m²/m
Largest joist spacing for the deflection limit
450 mm
Deflection at your spacing
0.25 mm
Your spacing ÷ deflection
1,215
Bending stress at your spacing (wL²/8)
1.57 N/mm²
Send this with your specification

Planning estimate, not a design check. A qualified engineer sets the loads, the panel values from its declaration of performance and the deflection limit, and signs off the formwork design.

Reference table

Largest joist spacing by thickness

Walls need much closer studs than slabs need joists, which is why 18 mm and 21 mm panels are the usual wall choice and why a thinner sheet suits only light slab work at close joists. These figures check stiffness only; bending, shear and the joists themselves are the engineer’s check.

Planning estimate: three or more spans, span ÷ 360, thickness minus 0.5 mm
ThicknessSlab 200 mm, E 40 (3,600 N/mm²)Slab 200 mm, E 60 (5,400 N/mm²)Wall 38.4 kN/m², E 40Wall 38.4 kN/m², E 60
12 mmabout 296 mmabout 338 mmabout 169 mmabout 193 mm
15 mmabout 373 mmabout 427 mmabout 212 mmabout 243 mm
18 mmabout 450 mmabout 515 mmabout 256 mmabout 294 mm
21 mmabout 527 mmabout 603 mmabout 300 mmabout 344 mm

Slab load = 2,400 kg/m³ × 9.81 × 0.2 m = 4.71 kN/m² plus 2.4 kN/m² live load = 7.11 kN/m². The wall pressure of 38.4 kN/m² is the ACI 347R-14 value for a 3 m wall poured at 1.5 m/h at 20 °C. Face grain runs across the joists.

Underside of slab formwork: film-faced plywood on evenly spaced timber beams and steel props
Panels span between evenly spaced timber beams; the gap is what the calculator sets.

How the numbers work

Formulas, sources and limits

The deflection limit is a project choice: a university formwork design example in the sources below limits form members to span ÷ 360, and the calculator starts there. Formwork self-weight, point loads from stacked materials and impact are not included. This is a planning estimate, not a design check: a qualified engineer sets the loads, takes the panel values from its declaration of performance and signs off the design.

What the span estimate assumes
ItemFormula or valueSource
Slab load wmax(ρ × g × depth + live load, 4.8 kN/m²)ACI 347R-14 §4.2.1: live load at least 2.4 kN/m², dead plus live at least 4.8 kN/m²
Stiffness EI per metreE × 1000 × (t − tolerance)³ ÷ 12Gross section with the EN 310 modulus of the whole panel
Deflectionw × L⁴ ÷ (k × EI); k = 145 (three or more spans), 185 (two), 76.8 (one)Beam formulas for a uniform load
Largest spacing(k × EI ÷ (limit × w))^(1/3)Deflection = span ÷ limit
Bending stress(w × L² ÷ 8) ÷ (1000 × t² ÷ 6)Conservative moment; compared by the engineer with the declared strength
Stiffness EEN 636 class lower limits, E 30 to E 80EN 636:2012+A1:2015 Table 2; not for structural design
Thicknessnominal minus 0.5 mmOur film-faced tolerance ±0.5 mm
18 mm film-faced plywood sheet spanning between two steel trestles
A sheet spanning two supports, the way a panel spans between joists.

What we claim

Why we give no stress grade

Our film-faced plywood is certified to AS 6669:2016 Plywood – Formwork by CMI Certification, and its CE marking runs under EN 13986 with factory production control certificate 0407-CPR-2146 for structural plywood 3.6–30 mm. Neither certificate states a stress grade, so we claim none. Performance values per thickness go on the declaration of performance, not on this page.

The thickness tolerance is ±0.5 mm on film-faced panels and is written on the technical sheet for each order. Stiffness grows with the cube of the thickness, so the tool takes the 0.5 mm off: at 18 mm that lowers the stiffness by about 8 % and the largest span by about 3 %.

Underside of slab formwork: film-faced panel joint over a timber I-beam
Panel joints land on a beam.

FAQ

Questions about formwork plywood span

How far can formwork plywood span?

As a planning estimate, 18 mm film-faced plywood with a bending stiffness of 3,600 N/mm² spans about 450 mm under a 200 mm slab at span ÷ 360 on three or more spans; 12 mm about 296 mm and 21 mm about 527 mm. A qualified engineer confirms the actual spacing.

What joist spacing suits 18 mm film-faced plywood under a slab?

At EN 636 class E 40 the stiffness limit gives about 450 mm under a 200 mm slab; a joist grid at 300 mm or 400 mm sits inside it. At class E 60 the estimate rises to about 515 mm. Bending, shear and the joists are checked separately by the engineer.

What deflection limit should formwork plywood meet?

The project specification and your engineer set it. The calculator starts at span ÷ 360, the limit used in a published formwork design example, and you can change it.

Which thickness should I choose for walls versus slabs?

Walls carry far more pressure: 38.4 kN/m² on a 3 m wall poured at 1.5 m/h at 20 °C against about 7.1 kN/m² under a 200 mm slab. That brings the stiffness spacing for 18 mm down to about 256 mm, so walls usually take 18 or 21 mm with close studs.

Does the thickness tolerance change the span result?

Slightly. Taking 0.5 mm off an 18 mm panel lowers its stiffness by about 8 % and the largest spacing by about 3 %. The tool does this by default.

Do you claim a stress grade for your formwork plywood?

No. Our AS 6669 formwork certificate and our CE factory production control certificate state no stress grade, so we claim none; performance values per thickness are on the declaration of performance.

Is this calculator an engineering design?

No. It is a planning estimate for comparing thicknesses and joist grids. A qualified engineer designs the formwork and signs it off.

Related pages

Panels, loading and the other calculators

CE marking

EN 13986 factory production control 0407-CPR-2146.

CE marking

Pour cost calculator

Your sheet price divided by the pours a build gives, per sheet and per m².

Pour cost calculator

Formwork plywood quantity

Contact area of slabs, walls and columns turned into sheets and a share of a 40HC.

Formwork plywood quantity

Landed cost

From an FOB Hai Phong price to landed cost per sheet and per pour.

Landed cost